• banner

Can micro peristaltic pumps pull vacuum?

 Micro peristaltic pump because of its accurate fluid handling capacity and no pollution and obtained remarkable popularity in various industries.One problem that engineers and technicians often encounter is whether these compact pumps - including specialized models such as mini peristaltic pumps, small peristaltic pumps and 12v peristaltic pumps - can effectively evacuate a vacuum.The answer than a simple "yes" or "no" more subtle, understand the working principle and limit is vital for the correct application.

The versatility of these pumps from basic micro peristaltic pump unit extend to a more professional configuration, such as used in mobile applications and industrial-grade peristaltic pump 12 VDC liquid pump system.Notably, the growing market for micro peristaltic pump manufacturers in China has made these technologies more accessible while maintaining high performance standards.Whether considering a compact micro peristaltic pump for laboratory use or a powerful 12v peristaltic pump for field applications, the basic working principle is the same, although their vacuum capability may vary depending on design specifications and power requirements.

How does a micro peristaltic pump produce a vacuum

The basic working principle of
The working principle of micro peristaltic pump is simple and effective.A rotating roller or slider compresses the hose, creating a temporary seal to deliver fluid or air to the outlet.When the hose returns to normal after the compression point, a low pressure area is created, sucking in more material.The process of this cycle, can on the inlet side of the vacuum pump in the export side at the same time maintain a positive pressure.
Key factors influencing the performances of vacuum
Several key factors that may influence the reliability of micro peristaltic pump vacuum:
1.the hose material and quality: the elasticity of hose and recovery characteristics directly affect the vacuum performance.
2.the pump head design: the number of roller and the compression institutions will affect the quality and stability of vacuum sealing.
3.motor power and speed, higher torque motor can maintain better vacuum under load.

Practical limitations of vacuum applications
Maximum vacuum
Micro peristaltic pumps can generate vacuum, but their vacuum is usually limited compared to specialty vacuum pumps.Most standard models have a maximum vacuum between -8 and -12 PSI, suitable for low to moderate vacuum applications, but not sufficient for high vacuum requirements.
Pipeline notes
Wire has both advantages and limitations in vacuum applications:
1. Collapse risk: Under high vacuum conditions, the pipe may collapse, resulting in the interruption of fluid flow.
2. Air permeability problem: some pipe materials allow air permeability, the limit can reach the ultimate vacuum.
3. Wear and maintenance: compression cycle will accelerate vacuum tube wear continuously.
Best applied in vacuum applications
Laboratory and research purposes
The micro peristaltic pump in the laboratory environment, outstanding:
1.It is crucial to handle liquids gently
2. Avoid cross contamination
Moderate vacuum can satisfy the requirement of filter or suction
Industrial applications
The pump has been successfully used in industrial environment, such as:
1. Sample absorption and delivery
2. Provide other pump system startup power
3. Low vacuum packaging applications

Common scenario
Vacuum operation best practices
Choose tubing correctly
Choose a pipe designed for vacuum applications and consider the following factors:
1. The wall thickness and reinforced
2. With the application of the material compatibility
3. The temperature tolerance
System design considerations
1. Shorten the pipe length between the vacuum source and the application equipment as much as possible
2. Make sure the support line is correct to prevent collapse
3. Apply the appropriate filter to protect pump
Maintenance and correction
Check regularly
Develop a comprehensive maintenance plan that includes:
1. Check the integrity of pipeline
2. Roller wear evaluation
3. The performance verification
Calibration to ensure stable performance
Regular calibration ensures the stability of vacuum performance:
1. The transport validation
2. Vacuum test
3. System integrity check

conclusion
Micro peristaltic pump can really pumping air into vacuum state, as the need to moderate level of vacuum application of effective solutions, with pollution-free operation and precise flow control of extra benefits.However, to understand the limitations of them is vital for successful implementation.When choosing a micro peristaltic pump for vacuum service, carefully consider the specific requirements of your application, including the necessary vacuum, flow rate, and maintenance capacity.Higher request for the application of vacuum, vacuum pump may be more appropriate for special purpose, but for many need to clean, appropriate laboratory and industrial application of the vacuum, micro peristaltic pump provides the ideal balance performance and practical solution.

you like also all


Post time: Nov-06-2025